{"id":1939,"date":"2021-11-02T10:00:00","date_gmt":"2021-11-02T15:00:00","guid":{"rendered":"https:\/\/gearmotorblog.wordpress.com\/?p=1939"},"modified":"2022-01-15T10:23:08","modified_gmt":"2022-01-15T16:23:08","slug":"bodine-gearmotor-constants","status":"publish","type":"post","link":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/","title":{"rendered":"Introduction to Motor Constants for Fractional Horsepower Gearmotors"},"content":{"rendered":"\n<p><strong>Motor constants are needed to calculate permanent magnet DC (PMDC) or brushless DC (BLDC or EC) motor specifications and ratings, or to match the motor properly to an amplifier. The motor constants&nbsp;are required in order to predict the&nbsp;PMDC or&nbsp;BLDC motor\u2019s performance with changing variables, such as different input voltages or different loads. (See below PDF link for Bodine stock PMDC and BLDC motor constants.) This application note explains what the constants are, how they are derived and how to use them. <\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg\" alt=\"Intro to Motor Constants for Bodine PMDC and BLDC Gearmotors and Motors\" class=\"wp-image-4661\" srcset=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg 800w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022-300x300.jpg 300w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022-150x150.jpg 150w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022-768x768.jpg 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><figcaption>Intro to Motor Constants for BLDC and PMDC Gearmotors and Motors<\/figcaption><\/figure>\n\n\n\n<p><strong>Common Motor Constants: <\/strong><\/p>\n\n\n\n<p>The most commonly used motor constants are Torque Constant (Kt), Voltage Constant (Ke),&nbsp;Electrical Time Constant (Te), Mechanical Time Constant (Tm), and Thermal Resistance (Rth). Typical values for these constants&nbsp;are derived by using measured values of No Load Speed, No Load Current, Stall Torque, Circuit Resistance, Circuit Inductance, and Armature Inertia with the following equations:<\/p>\n\n\n\n<p><strong>Torque Constant (Kt)<\/strong> &#8212; describes the proportional relationship&nbsp;between torque and current. Kt&nbsp;is usually expressed in the units Oz-in.\/Amp. See page&nbsp;2 for additional information about torque constants.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-03-26-20151.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"591\" height=\"62\" src=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-03-26-20151.jpg?w=300\" alt=\"Bodine Electric - Motor Constants - 03.26.2015\" class=\"wp-image-1955\" srcset=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-03-26-20151.jpg 591w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-03-26-20151-300x31.jpg 300w\" sizes=\"auto, (max-width: 591px) 100vw, 591px\" \/><\/a><\/figure>\n\n\n\n<p><strong>Voltage Constant, or Back EMF Constant (Ke)<\/strong> \u2014 is the Torque Constant expressed in different units, usually Volts\/Krpm, in order to describe the proportional relationship&nbsp;between motor speed and generated output voltage when the motor is back driven as a generator in units of Volts\/1000 rpm. See page&nbsp;2 for additional information about voltage constants.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-22.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"361\" height=\"37\" src=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-22.jpg?w=300\" alt=\"Bodine Electric - Motor Constants - 2\" class=\"wp-image-1951\" srcset=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-22.jpg 361w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-22-300x31.jpg 300w\" sizes=\"auto, (max-width: 361px) 100vw, 361px\" \/><\/a><\/figure>\n\n\n\n<p><strong>Electrical Time Constant (Te)<\/strong> \u2014 is the time required for a motor to reach 63.2% of its stall current after applying a test voltage with the motor shaft locked. It is usually expressed in milliseconds. Applied Voltage equals Rated Current multiplied by Circuit Resistance:<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-11.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"434\" height=\"99\" src=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-11.jpg?w=300\" alt=\"Bodine Electric - Motor Constants - 11\" class=\"wp-image-2013\" srcset=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-11.jpg 434w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-11-300x68.jpg 300w\" sizes=\"auto, (max-width: 434px) 100vw, 434px\" \/><\/a><\/figure>\n\n\n\n<p><strong>Mechanical Time Constant (Tm)<\/strong> \u2014 is the time required for an unloaded motor to reach 63.2% of its no load speed after applying its rated voltage. It is usually expressed in milliseconds.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/04\/bodine-gearmotor-motor-time-constants-51.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"358\" height=\"195\" src=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/04\/bodine-gearmotor-motor-time-constants-51.jpg?w=300\" alt=\"bodine-gearmotor-motor-time-constants-5\" class=\"wp-image-2069\" srcset=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/04\/bodine-gearmotor-motor-time-constants-51.jpg 358w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/04\/bodine-gearmotor-motor-time-constants-51-300x163.jpg 300w\" sizes=\"auto, (max-width: 358px) 100vw, 358px\" \/><\/a><\/figure>\n\n\n\n<p><strong>Thermal Resistance (Rth)<\/strong> \u2014 is useful for predicting the ultimate temperature rise under different loading conditions in order to determine a maximum continuous torque rating. It is usually expressed in the units \u00b0C\/Watt.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><a href=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-6.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"421\" height=\"43\" src=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-6.jpg?w=300\" alt=\"Bodine Electric - Motor Constants - 6\" class=\"wp-image-1966\" srcset=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-6.jpg 421w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-6-300x31.jpg 300w\" sizes=\"auto, (max-width: 421px) 100vw, 421px\" \/><\/a><\/figure>\n\n\n\n<p><strong>Using Performance Data to Calculate Kt and Ke<\/strong><\/p>\n\n\n\n<p>This speed\/torque graph demonstrates how the linear equation of the current is used to calculate the Torque Constant (Kt) by using the slope &#8220;m.&#8221; The Voltage Constant (Ke) can then be calculated.<\/p>\n\n\n\n<p><strong>Using Performance Data to Calculate Kt and Ke<\/strong><\/p>\n\n\n\n<p>This speed\/torque graph demonstrates how the linear equation of the current is&nbsp;used to calculate the Torque Constant (Kt) by using the slope &#8220;m.&#8221; The Voltage Constant (Ke) can then be calculated.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-81.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"1351\" height=\"511\" src=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-81.jpg\" alt=\"Bodine Electric - Motor Constants - 8\" class=\"wp-image-1999\" srcset=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-81.jpg 1351w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-81-300x113.jpg 300w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-81-768x290.jpg 768w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-81-1024x387.jpg 1024w\" sizes=\"auto, (max-width: 1351px) 100vw, 1351px\" \/><\/a><\/figure><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><a href=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-91.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"851\" height=\"725\" src=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-91.jpg\" alt=\"Bodine Electric - Motor Constants - 9\" class=\"wp-image-2000\" srcset=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-91.jpg 851w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-91-300x256.jpg 300w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2015\/03\/bodine-electric-motor-constants-91-768x654.jpg 768w\" sizes=\"auto, (max-width: 851px) 100vw, 851px\" \/><\/a><\/figure><\/div>\n\n\n\n<p>To download this information as a PDF<strong>, <a href=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/bodine-gearmotors-introduction-to-motor-constants-for-fractional-horsepower-07470050.pdf\">click here<\/a>.<br><\/strong><span style=\"font-size: inherit; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif;\">To download the <\/span><strong style=\"font-size: inherit; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif;\">Motor Constants<\/strong><span style=\"font-size: inherit; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif;\"> for Standard Bodine&nbsp;Gearmotors, <\/span><strong style=\"font-size: inherit; font-family: -apple-system, BlinkMacSystemFont, 'Segoe UI', Roboto, Oxygen-Sans, Ubuntu, Cantarell, 'Helvetica Neue', sans-serif;\"><a href=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/12\/bodine-gearmotors-introduction-to-motor-contants-for-standard-motors-07470050.pdf\">click here<\/a>.<br><\/strong>To download&nbsp;Chapter 8, or any other section of the<strong>&nbsp;Bodine Small Motors Handbook, <a title=\"Download the Bodine Handbook (PDF)\" href=\"http:\/\/www.bodine-electric.com\/handbook\" target=\"_blank\" rel=\"noopener noreferrer\">click here<\/a>. <\/strong><\/p>\n\n\n\n<p><strong>Bonus Tech Tip:<\/strong> Another handy use for motor constants is when performing load measurements. If you are designing a machine and want to use an AC gearmotor, but you don\u2019t know what size gearmotor you need. AC motors don\u2019t have torque constants, but DC motors do. You might install a DC gearmotor into your prototype machine and use it as a \u201ctorque transducer\u201d. By measuring the current draw, you can estimate what torque is needed when you start shopping for the AC gearmotor on Bodine Electric Company\u2019s website<\/p>\n\n\n\n<p class=\"has-text-align-center\">Copyright <a title=\"Bodine Electric Home Page\" href=\"http:\/\/www.bodine-electric.com\/\" target=\"_blank\" rel=\"noopener noreferrer\">Bodine Electric Company<\/a> \u00a9 11\/2021. All rights reserved.<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"Motor constants are needed to calculate permanent magnet DC (PMDC) or brushless DC (BLDC or EC) motor specifications and ratings, or to match the motor properly to an amplifier. The motor constants&nbsp;are required in order to predict the&nbsp;PMDC or&nbsp;BLDC motor\u2019s performance with changing variables, such as different input voltages or different loads. (See below PDF<br \/><br \/><br \/><br \/><a class=\"view_link\" href=\"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/\"> VIEW<\/a>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2,6,7],"tags":[21,22,24,48,67],"class_list":["post-1939","post","type-post","status-publish","format-standard","hentry","category-application-tips","category-engineering-talk","category-gearmotor-basics","tag-bodine-electric-company","tag-bodine-handbook","tag-brushless-dc-gearmotor","tag-permanent-magnet-dc-gearmotors","tag-variable-speed-gearmotors"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Introduction to Motor Constants for Fractional Horsepower Gearmotors - Bodine - Gearmotor Blog<\/title>\n<meta name=\"description\" content=\"Motor constants are needed to calculate permanent magnet DC (PMDC) or brushless DC (BLDC or EC) motor or gearmotor specifications and ratings\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Introduction to Motor Constants for Fractional Horsepower Gearmotors - Bodine - Gearmotor Blog\" \/>\n<meta property=\"og:description\" content=\"Motor constants are needed to calculate permanent magnet DC (PMDC) or brushless DC (BLDC or EC) motor or gearmotor specifications and ratings\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/\" \/>\n<meta property=\"og:site_name\" content=\"Bodine - Gearmotor Blog\" \/>\n<meta property=\"article:published_time\" content=\"2021-11-02T15:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-01-15T16:23:08+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg\" \/>\n<meta name=\"author\" content=\"Edmund Glueck\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Edmund Glueck\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/\"},\"author\":{\"name\":\"Edmund Glueck\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/#\\\/schema\\\/person\\\/10501f44e9d7ebb8c2796452c87f9574\"},\"headline\":\"Introduction to Motor Constants for Fractional Horsepower Gearmotors\",\"datePublished\":\"2021-11-02T15:00:00+00:00\",\"dateModified\":\"2022-01-15T16:23:08+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/\"},\"wordCount\":580,\"image\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg\",\"keywords\":[\"Bodine Electric Company\",\"Bodine Handbook\",\"Brushless DC Gearmotor\",\"Permanent Magnet DC Gearmotors\",\"Variable Speed Gearmotors\"],\"articleSection\":[\"Application Tips\",\"Engineering Talk\",\"Gearmotor Basics\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/\",\"url\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/\",\"name\":\"Introduction to Motor Constants for Fractional Horsepower Gearmotors - Bodine - Gearmotor Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg\",\"datePublished\":\"2021-11-02T15:00:00+00:00\",\"dateModified\":\"2022-01-15T16:23:08+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/#\\\/schema\\\/person\\\/10501f44e9d7ebb8c2796452c87f9574\"},\"description\":\"Motor constants are needed to calculate permanent magnet DC (PMDC) or brushless DC (BLDC or EC) motor or gearmotor specifications and ratings\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg\",\"contentUrl\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/wp-content\\\/uploads\\\/2021\\\/11\\\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg\",\"width\":800,\"height\":800,\"caption\":\"Intro to Motor Constants for Bodine PMDC and BLDC Gearmotors and Motors\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/bodine-gearmotor-constants\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Introduction to Motor Constants for Fractional Horsepower Gearmotors\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/\",\"name\":\"Bodine - Gearmotor Blog\",\"description\":\"We Drive the World&#039;s Leading Products!\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/#\\\/schema\\\/person\\\/10501f44e9d7ebb8c2796452c87f9574\",\"name\":\"Edmund Glueck\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g\",\"caption\":\"Edmund Glueck\"},\"sameAs\":[\"http:\\\/\\\/www.bodine-electric.com\"],\"url\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/author\\\/gearmotorblog\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Introduction to Motor Constants for Fractional Horsepower Gearmotors - Bodine - Gearmotor Blog","description":"Motor constants are needed to calculate permanent magnet DC (PMDC) or brushless DC (BLDC or EC) motor or gearmotor specifications and ratings","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/","og_locale":"en_US","og_type":"article","og_title":"Introduction to Motor Constants for Fractional Horsepower Gearmotors - Bodine - Gearmotor Blog","og_description":"Motor constants are needed to calculate permanent magnet DC (PMDC) or brushless DC (BLDC or EC) motor or gearmotor specifications and ratings","og_url":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/","og_site_name":"Bodine - Gearmotor Blog","article_published_time":"2021-11-02T15:00:00+00:00","article_modified_time":"2022-01-15T16:23:08+00:00","og_image":[{"url":"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg","type":"","width":"","height":""}],"author":"Edmund Glueck","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Edmund Glueck","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/#article","isPartOf":{"@id":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/"},"author":{"name":"Edmund Glueck","@id":"https:\/\/www.bodine-electric.com\/blog\/#\/schema\/person\/10501f44e9d7ebb8c2796452c87f9574"},"headline":"Introduction to Motor Constants for Fractional Horsepower Gearmotors","datePublished":"2021-11-02T15:00:00+00:00","dateModified":"2022-01-15T16:23:08+00:00","mainEntityOfPage":{"@id":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/"},"wordCount":580,"image":{"@id":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/#primaryimage"},"thumbnailUrl":"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg","keywords":["Bodine Electric Company","Bodine Handbook","Brushless DC Gearmotor","Permanent Magnet DC Gearmotors","Variable Speed Gearmotors"],"articleSection":["Application Tips","Engineering Talk","Gearmotor Basics"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/","url":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/","name":"Introduction to Motor Constants for Fractional Horsepower Gearmotors - Bodine - Gearmotor Blog","isPartOf":{"@id":"https:\/\/www.bodine-electric.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/#primaryimage"},"image":{"@id":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/#primaryimage"},"thumbnailUrl":"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg","datePublished":"2021-11-02T15:00:00+00:00","dateModified":"2022-01-15T16:23:08+00:00","author":{"@id":"https:\/\/www.bodine-electric.com\/blog\/#\/schema\/person\/10501f44e9d7ebb8c2796452c87f9574"},"description":"Motor constants are needed to calculate permanent magnet DC (PMDC) or brushless DC (BLDC or EC) motor or gearmotor specifications and ratings","breadcrumb":{"@id":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/#primaryimage","url":"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg","contentUrl":"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2021\/11\/Bodine-gearmotors-Intro-to-motor-constants-blog-2022.jpg","width":800,"height":800,"caption":"Intro to Motor Constants for Bodine PMDC and BLDC Gearmotors and Motors"},{"@type":"BreadcrumbList","@id":"https:\/\/www.bodine-electric.com\/blog\/bodine-gearmotor-constants\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.bodine-electric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Introduction to Motor Constants for Fractional Horsepower Gearmotors"}]},{"@type":"WebSite","@id":"https:\/\/www.bodine-electric.com\/blog\/#website","url":"https:\/\/www.bodine-electric.com\/blog\/","name":"Bodine - Gearmotor Blog","description":"We Drive the World&#039;s Leading Products!","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.bodine-electric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.bodine-electric.com\/blog\/#\/schema\/person\/10501f44e9d7ebb8c2796452c87f9574","name":"Edmund Glueck","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g","caption":"Edmund Glueck"},"sameAs":["http:\/\/www.bodine-electric.com"],"url":"https:\/\/www.bodine-electric.com\/blog\/author\/gearmotorblog\/"}]}},"_links":{"self":[{"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/posts\/1939","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/comments?post=1939"}],"version-history":[{"count":18,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/posts\/1939\/revisions"}],"predecessor-version":[{"id":4846,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/posts\/1939\/revisions\/4846"}],"wp:attachment":[{"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/media?parent=1939"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/categories?post=1939"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/tags?post=1939"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}