{"id":895,"date":"2012-04-26T09:52:30","date_gmt":"2012-04-26T14:52:30","guid":{"rendered":"http:\/\/gearmotorblog.wordpress.com\/?p=895"},"modified":"2020-05-13T22:51:58","modified_gmt":"2020-05-13T22:51:58","slug":"armature-resistance-dc-motors","status":"publish","type":"post","link":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/","title":{"rendered":"Measuring Armature Circuit Resistance in a PMDC Motor"},"content":{"rendered":"<p><strong>Application Notes &amp; Gearmotor Tips:<\/strong><\/p>\n<div id=\"attachment_910\" style=\"width: 310px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-910\" class=\"size-medium wp-image-910\" title=\"Permanent Magnet DC (PMDC) Motor and Gearmotors\" src=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg?w=300\" alt=\"\" width=\"300\" height=\"198\" srcset=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2012\/04\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg 881w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2012\/04\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50-300x198.jpg 300w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2012\/04\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50-768x507.jpg 768w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/a><p id=\"caption-attachment-910\" class=\"wp-caption-text\">Permanent Magnet DC (PMDC) Motor and Gearmotors<\/p><\/div>\n<p>When a permanent magnet DC (PMDC) motor fails to operate properly, or fails to run at all, one sensible troubleshooting step is to measure the winding resistance to determine if there\u2019s an open circuit or a short circuit, either between turns of the same winding, between two windings in the same motor, or between a winding and ground. This is a fairly simple procedure using an ohmmeter on an AC motor or a brushless DC motor, but it is not so simple with a brush type (PM) DC motor or gearmotor.<\/p>\n<p><strong><em>Since an ohmmeter can\u2019t be used to directly measure the armature circuit resistance in a PMDC motor or gearmotor, the resistance has to be calculated.<\/em><\/strong><\/p>\n<p>If you have tried to measure armature circuit resistance with an ohmmeter (via the motor leads), you have found that the result is an unusually high reading. You might have thought that the armature was in a position where the brushes were bridging two commutator bars on each side. But turning the armature provided no better resistance reading. This is because armature circuit resistance cannot be measured accurately with an ohmmeter.<\/p>\n<p>Because the connection between the brushes and the commutator is not a solid one, the gap between the two components represents additional resistance to the low voltage and low current of a typical ohmmeter power source. The additional resistance comes from the oxide film formed on the surface of the commutator and the free particles in the gap, as shown in the image below (the graphitic film is conductive). The same oxide film and free particles don\u2019t represent a significant resistance to the higher voltage and higher current of a typical DC motor power supply. Since an ohmmeter can\u2019t be used to directly measure the armature circuit resistance, the resistance has to be calculated.<\/p>\n<div id=\"attachment_902\" style=\"width: 510px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/07470033-brush-gap_photo_04-23-2012_50.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-902\" class=\"size-full wp-image-902\" title=\"Magnified view: brush and commutator - PMDC motor\" src=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/07470033-brush-gap_photo_04-23-2012_50.jpg\" alt=\"\" width=\"500\" height=\"466\" srcset=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2012\/04\/07470033-brush-gap_photo_04-23-2012_50.jpg 822w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2012\/04\/07470033-brush-gap_photo_04-23-2012_50-300x280.jpg 300w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2012\/04\/07470033-brush-gap_photo_04-23-2012_50-768x717.jpg 768w\" sizes=\"auto, (max-width: 500px) 100vw, 500px\" \/><\/a><p id=\"caption-attachment-902\" class=\"wp-caption-text\">Magnified view: brush and commutator &#8211; PMDC motor (Bodine Electric Company)<\/p><\/div>\n<p><strong>Test Procedure:<\/strong><\/p>\n<p>1.\u00a0\u00a0\u00a0\u00a0\u00a0 Before the armature circuit resistance can be calculated, the motor must be set up in a way such that both the armature and the motor frame are not permitted to turn. In the case of a gearmotor with a fairly high gear ratio, this could require a rather sturdy restraint. However, the stall torque of a DC motor is proportional to the applied voltage, so reduce the voltage until you are able to hold the gearmotor in place with the armature locked.<\/p>\n<p>2.\u00a0\u00a0\u00a0\u00a0\u00a0 Make sure that the voltage is still high enough to drive a current of at least 10% of the motor\u2019s nameplate rating or 0.25 Amp, whichever is higher.<\/p>\n<p>3.\u00a0\u00a0\u00a0\u00a0\u00a0 Starting with a \u201ccool\u201d motor (meaning the winding temperature is the same as the ambient, which should be at a normal room temperature of<br \/>\n+25\u00b0 C [+77\u00b0F]), measure the applied voltage and the current draw at least five times, with the armature in a different angular position each time.<\/p>\n<p>4.\u00a0\u00a0\u00a0\u00a0\u00a0 Do each test quickly to keep the motor from heating up, because winding resistance changes with temperature and these changes would affect the accuracy of the tests.<\/p>\n<p>The armature circuit resistance can then be calculated by using the following basic steady state DC motor equation:<\/p>\n<p>E = I x R + (Ke x w), where<\/p>\n<p>E = applied voltage<\/p>\n<p>I = current<\/p>\n<p>R = armature circuit resistance<\/p>\n<p>Ke = voltage constant<\/p>\n<p>w = speed (omega)<\/p>\n<p>Since speed = 0 with the armature locked in place, the back emf voltage (Ke x w) = 0 and the equation can be simplified to:<\/p>\n<p>E = I x R<\/p>\n<p>This can be rewritten to solve for the armature circuit resistance:<\/p>\n<p>R = E\/I<\/p>\n<p>Use this equation with the current and voltage measurements from each of the five tests and then average the results for the resistance. Even if you never use this method yourself, you can now explain to your customers why they have not been able to measure the correct armature circuit resistance with an ohmmeter and then suggest this more reliable method.<\/p>\n<p>You can <strong>download the <a title=\"Bodine Application Note - Armature Resistance\" href=\"https:\/\/www.bodine-electric.com\/core\/files\/bodineelectric\/resources\/bodine-dc-gearmotor-armature-resistance-07470033-A.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">PDF version<\/a><\/strong> of this application note <strong>by <a title=\"Bodine Application Note - Armature Resistance\" href=\"https:\/\/www.bodine-electric.com\/core\/files\/bodineelectric\/resources\/bodine-dc-gearmotor-armature-resistance-07470033-A.pdf\" target=\"_blank\" rel=\"noopener noreferrer\">clicking on this link<\/a><\/strong>.<\/p>\n<p><strong>Examples:<\/strong><\/p>\n<p>1.\u00a0\u00a0\u00a0\u00a0\u00a0 <strong>Bodine Model 6422 <\/strong>(24 VDC, type 33A7)<strong><br \/>\n<\/strong>B+K Precision multimeter reading: 0.674 \u03a9<br \/>\nThis test method: 0.196 \u03a9<\/p>\n<p>1.\u00a0\u00a0\u00a0\u00a0\u00a0 <strong>Bodine Model 6035 <\/strong>(130 VDC, type 33A5)<br \/>\nB+K Precision multimeter reading: 11.41 \u03a9<br \/>\nThis test method: 11.13 \u03a9<\/p>\n<div id=\"attachment_907\" style=\"width: 160px\" class=\"wp-caption alignright\"><a href=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/07470033-armature-comm_rctgl-crop_25.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-907\" class=\"size-thumbnail wp-image-907\" title=\"Typical PMDC motor armature and winding assembly - Bodine Electric Co.\" src=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/07470033-armature-comm_rctgl-crop_25.jpg?w=150\" alt=\"\" width=\"150\" height=\"107\" srcset=\"https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2012\/04\/07470033-armature-comm_rctgl-crop_25.jpg 523w, https:\/\/www.bodine-electric.com\/blog\/wp-content\/uploads\/2012\/04\/07470033-armature-comm_rctgl-crop_25-300x216.jpg 300w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/a><p id=\"caption-attachment-907\" class=\"wp-caption-text\">Wound PMDC motor armature with commutator.<\/p><\/div>\n<p><strong>Note: <\/strong>The bar-to-bar resistance\u00a0measured directly between two opposing commutator bars does not\u00a0provide the &#8220;full picture&#8221;. The armature circuit resistance provides the sum of resistances in the PMDC motor &#8212;\u00a0from the commutator to the external motor\u00a0cord and everything in-between (brushes,\u00a0brush holders, springs, winding,\u00a0terminals, etc.)<\/p>\n<p>Copyright\u00a0 <a title=\"Bodine Electric Company Home Page\" href=\"http:\/\/www.bodine-electric.com\/\" target=\"_blank\" rel=\"noopener noreferrer\">Bodine Electric Company <\/a>\u00a9\u00a0 04\/2012.\u00a0 All rights reserved.<\/p>\n","protected":false},"excerpt":{"rendered":"Application Notes &amp; Gearmotor Tips: When a permanent magnet DC (PMDC) motor fails to operate properly, or fails to run at all, one sensible troubleshooting step is to measure the winding resistance to determine if there\u2019s an open circuit or a short circuit, either between turns of the same winding, between two windings in the<br \/><br \/><br \/><br \/><a class=\"view_link\" href=\"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/\"> VIEW<\/a>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[2,6,7],"tags":[21,34,35,48,53],"class_list":["post-895","post","type-post","status-publish","format-standard","hentry","category-application-tips","category-engineering-talk","category-gearmotor-basics","tag-bodine-electric-company","tag-fractional-horsepower","tag-gearmotor","tag-permanent-magnet-dc-gearmotors","tag-pmdc-motors"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Measuring Armature Circuit Resistance in a PMDC Motor - Bodine - Gearmotor Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Measuring Armature Circuit Resistance in a PMDC Motor - Bodine - Gearmotor Blog\" \/>\n<meta property=\"og:description\" content=\"Application Notes &amp; Gearmotor Tips: When a permanent magnet DC (PMDC) motor fails to operate properly, or fails to run at all, one sensible troubleshooting step is to measure the winding resistance to determine if there\u2019s an open circuit or a short circuit, either between turns of the same winding, between two windings in the\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/\" \/>\n<meta property=\"og:site_name\" content=\"Bodine - Gearmotor Blog\" \/>\n<meta property=\"article:published_time\" content=\"2012-04-26T14:52:30+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-05-13T22:51:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg?w=300\" \/>\n<meta name=\"author\" content=\"Edmund Glueck\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Edmund Glueck\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/\"},\"author\":{\"name\":\"Edmund Glueck\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/#\\\/schema\\\/person\\\/10501f44e9d7ebb8c2796452c87f9574\"},\"headline\":\"Measuring Armature Circuit Resistance in a PMDC Motor\",\"datePublished\":\"2012-04-26T14:52:30+00:00\",\"dateModified\":\"2020-05-13T22:51:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/\"},\"wordCount\":789,\"image\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/\\\/wp-content\\\/uploads\\\/2012\\\/04\\\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg?w=300\",\"keywords\":[\"Bodine Electric Company\",\"Fractional Horsepower\",\"Gearmotor\",\"Permanent Magnet DC Gearmotors\",\"pmdc motors\"],\"articleSection\":[\"Application Tips\",\"Engineering Talk\",\"Gearmotor Basics\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/\",\"url\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/\",\"name\":\"Measuring Armature Circuit Resistance in a PMDC Motor - Bodine - Gearmotor Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/\\\/wp-content\\\/uploads\\\/2012\\\/04\\\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg?w=300\",\"datePublished\":\"2012-04-26T14:52:30+00:00\",\"dateModified\":\"2020-05-13T22:51:58+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/#\\\/schema\\\/person\\\/10501f44e9d7ebb8c2796452c87f9574\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/\\\/wp-content\\\/uploads\\\/2012\\\/04\\\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg?w=300\",\"contentUrl\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/\\\/wp-content\\\/uploads\\\/2012\\\/04\\\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg?w=300\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/armature-resistance-dc-motors\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Measuring Armature Circuit Resistance in a PMDC Motor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/\",\"name\":\"Bodine - Gearmotor Blog\",\"description\":\"We Drive the World&#039;s Leading Products!\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/#\\\/schema\\\/person\\\/10501f44e9d7ebb8c2796452c87f9574\",\"name\":\"Edmund Glueck\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g\",\"caption\":\"Edmund Glueck\"},\"sameAs\":[\"http:\\\/\\\/www.bodine-electric.com\"],\"url\":\"https:\\\/\\\/www.bodine-electric.com\\\/blog\\\/author\\\/gearmotorblog\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Measuring Armature Circuit Resistance in a PMDC Motor - Bodine - Gearmotor Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/","og_locale":"en_US","og_type":"article","og_title":"Measuring Armature Circuit Resistance in a PMDC Motor - Bodine - Gearmotor Blog","og_description":"Application Notes &amp; Gearmotor Tips: When a permanent magnet DC (PMDC) motor fails to operate properly, or fails to run at all, one sensible troubleshooting step is to measure the winding resistance to determine if there\u2019s an open circuit or a short circuit, either between turns of the same winding, between two windings in the","og_url":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/","og_site_name":"Bodine - Gearmotor Blog","article_published_time":"2012-04-26T14:52:30+00:00","article_modified_time":"2020-05-13T22:51:58+00:00","og_image":[{"url":"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg?w=300","type":"","width":"","height":""}],"author":"Edmund Glueck","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Edmund Glueck","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/#article","isPartOf":{"@id":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/"},"author":{"name":"Edmund Glueck","@id":"https:\/\/www.bodine-electric.com\/blog\/#\/schema\/person\/10501f44e9d7ebb8c2796452c87f9574"},"headline":"Measuring Armature Circuit Resistance in a PMDC Motor","datePublished":"2012-04-26T14:52:30+00:00","dateModified":"2020-05-13T22:51:58+00:00","mainEntityOfPage":{"@id":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/"},"wordCount":789,"image":{"@id":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/#primaryimage"},"thumbnailUrl":"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg?w=300","keywords":["Bodine Electric Company","Fractional Horsepower","Gearmotor","Permanent Magnet DC Gearmotors","pmdc motors"],"articleSection":["Application Tips","Engineering Talk","Gearmotor Basics"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/","url":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/","name":"Measuring Armature Circuit Resistance in a PMDC Motor - Bodine - Gearmotor Blog","isPartOf":{"@id":"https:\/\/www.bodine-electric.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/#primaryimage"},"image":{"@id":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/#primaryimage"},"thumbnailUrl":"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg?w=300","datePublished":"2012-04-26T14:52:30+00:00","dateModified":"2020-05-13T22:51:58+00:00","author":{"@id":"https:\/\/www.bodine-electric.com\/blog\/#\/schema\/person\/10501f44e9d7ebb8c2796452c87f9574"},"breadcrumb":{"@id":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/#primaryimage","url":"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg?w=300","contentUrl":"https:\/\/www.bodine-electric.com\/blog\/\/wp-content\/uploads\/2012\/04\/dc-mtr-grmtr-group_crop-whitte_04-25-2012_50.jpg?w=300"},{"@type":"BreadcrumbList","@id":"https:\/\/www.bodine-electric.com\/blog\/armature-resistance-dc-motors\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.bodine-electric.com\/blog\/"},{"@type":"ListItem","position":2,"name":"Measuring Armature Circuit Resistance in a PMDC Motor"}]},{"@type":"WebSite","@id":"https:\/\/www.bodine-electric.com\/blog\/#website","url":"https:\/\/www.bodine-electric.com\/blog\/","name":"Bodine - Gearmotor Blog","description":"We Drive the World&#039;s Leading Products!","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.bodine-electric.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.bodine-electric.com\/blog\/#\/schema\/person\/10501f44e9d7ebb8c2796452c87f9574","name":"Edmund Glueck","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/362f68efaf5bb6d0e1e41a48423131ce5803c21bf55ada86847357d0d5c8f831?s=96&d=identicon&r=g","caption":"Edmund Glueck"},"sameAs":["http:\/\/www.bodine-electric.com"],"url":"https:\/\/www.bodine-electric.com\/blog\/author\/gearmotorblog\/"}]}},"_links":{"self":[{"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/posts\/895","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/comments?post=895"}],"version-history":[{"count":4,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/posts\/895\/revisions"}],"predecessor-version":[{"id":4228,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/posts\/895\/revisions\/4228"}],"wp:attachment":[{"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/media?parent=895"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/categories?post=895"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.bodine-electric.com\/blog\/wp-json\/wp\/v2\/tags?post=895"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}